Navien · NPE-A2 condensing tankless (NPE-180A2 / NPE-210A2 / NPE-240A2) · Gas tankless

Navien NPE-240A2

The Navien NPE-240A2 is the largest of Navien's Canadian A2 condensing tankless models: 13,300–199,900 BTU/h on natural gas or propane, UEF 0.95, and published flows of 11.2 GPM at a 35 °F rise and 5.6 GPM at a 67 °F rise. It is a wall-hung, forced-draft direct-vent unit.

CurrentSold in Canada

Key figures

Max input
199,900 BTU/h
Flow at 35 °F (19.4 °C) rise
11.2 GPM (42.4 L/min)
Uniform Energy Factor (UEF)
0.95
Natural gasPropaneCondensing, PVC/CPVC/PPresidential

Flow figures depend on temperature rise; compare only at the same rise. Max flow is not guaranteed winter performance.

Navien NPE-240A2 in practice

The NPE-240A2 is Navien's flagship A2 tankless model and one of the most common Navien units in Metro Vancouver tankless work. Its capacity is published as flow at three temperature rises rather than one maximum: 11.2 GPM (42.4 L/min) at a 35 °F rise, 8.7 GPM at 45 °F, and 5.6 GPM at 67 °F. Because Metro Vancouver's winter incoming water can sit below 8 °C, reaching 49 °C is roughly a 40 °C (72 °F) rise, and the flow figures at and above a 45 °F rise are the ones a sizing assessment uses.

The unit is wall-hung, vents as a forced-draft direct vent in 2 in or 3 in PVC-family or approved stainless/BH pipe with zero clearance to combustibles, and runs on 120 V. Its stainless steel primary and secondary heat exchangers are the platform's corrosion story, and recirculation is supported through Navien's ComfortFlow configuration with an external pump or crossover accessory. Whether CANRO stocks this model for a given job is confirmed at consultation.

Best suited to

  • Larger homes converting to tankless where the winter flow at rise is assessed honestly
  • Two-bathroom households with occasional simultaneous use
  • Installations wanting stainless heat exchangers and published flow-at-rise ratings

Limitations to know

  • Winter delivery at a 67 °F-class rise is 5.6 GPM: two simultaneous showers are marginal
  • Requires 120 V power; no hot water during an outage
  • Needs a sealed 2 in or 3 in vent route and a condensate drain
  • Navien's published resale policy voids warranty for internet or e-commerce purchases; supply runs through contractors

Applicability and support

Model number
NPE-240A2
Variants on this page
None
Canadian availability
available
Production status
current
CANRO supplies
Confirmed at consultation
CANRO services
Confirmed at consultation
Recirculation
Yes, external pump and piping required
Warranty
Not verified

The A2 platform supports Navien's ComfortFlow recirculation with an external pump or a crossover-valve accessory; energy consumption rises when recirculation is configured. Recirculation shortens, not eliminates, the wait at the tap.

Where CANRO provides on-site service

On-site service is currently offered across Metro Vancouver: Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Delta, Langley, Port Moody, Port Coquitlam, Maple Ridge, Pitt Meadows, White Rock, Tsawwassen; plus Anmore, Belcarra, Lions Bay, Bowen Island, Abbotsford with travel or ferry arrangements confirmed by phone. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Navien. Manufacturer gallon and BTU/h figures are preserved with metric alongside; notes flag conflicting documents and missing figures. Groups expand for detail.

Flow (tankless) 4
Navien NPE-240A2 specifications: Flow (tankless)
SpecificationValueNote
Flow at a 35 °F (19.4 °C) rise11.2 GPM (42.4 L/min) at 35 °F (19.4 °C) riseNavien's published rating table.
Flow at a 45 °F (25 °C) rise8.7 GPM (32.9 L/min) at 45 °F (25 °C) riseNavien's published rating table.
Flow at a 67 °F (37.2 °C) rise5.6 GPM (21.2 L/min) at 67 °F (37.2 °C) riseNavien's published rating table; the winter rise in Metro Vancouver is in this range.
Minimum flow rate0.5 GPM (1.9 L/min); under 0.01 GPM option in ComfortFlow modePer Navien's specification table.
Input 2
Navien NPE-240A2 specifications: Input
SpecificationValueNote
Minimum gas input13,300 BTU/h3.9 kW. Natural gas and propane per Navien.
Maximum gas input199,900 BTU/h58.6 kW. Natural gas and propane per Navien.
Efficiency 1
Navien NPE-240A2 specifications: Efficiency
SpecificationValueNote
Uniform Energy Factor (UEF)0.95Natural gas and propane per Navien's specification table.
Venting and air 1
Navien NPE-240A2 specifications: Venting and air
SpecificationValueNote
Vent type2 in or 3 in PVC, CPVC, approved polypropylene or stainless steel; special gas vent type BH (Class II A/B/C)Forced-draft direct vent per Navien; zero clearance to combustibles.
Connections 2
Navien NPE-240A2 specifications: Connections
SpecificationValueNote
Gas connection3/4 inNG supply pressure 3.5–10.5 in. w.c.; propane 8–13 in. w.c.
Water connections3/4 in cold inlet and hot outlet
Electrical 1
Navien NPE-240A2 specifications: Electrical
SpecificationValueNote
Electrical supply120 V AC, 60 Hz; up to 200 W (2 A), 350 W (4 A) with external pump
Physical 4
Navien NPE-240A2 specifications: Physical
SpecificationValueNote
Height27.4 in (696 mm)
Width17.3 in (439 mm)
Depth13.2 in (335 mm)
Weight77 lb (34.9 kg)
Operating limits 2
Navien NPE-240A2 specifications: Operating limits
SpecificationValueNote
Maximum altitude10,100 ft for natural gas and propanePer Navien; the installation manual has the details.
CertificationListed with flame rod, air-pressure switch, ignition-operation detector and high-limit safety devicesSafety devices per Navien's specification table.

Manuals

Maintenance the manufacturer specifies

  • Flush (descale) the heat exchanger periodically per Navien's maintenance guidance; scale damage is not covered by warranty.
  • Clean the water inlet filter as part of the service interval.
  • Check the condensate drain and trap for flow and blockage at service.
  • Confirm the correct vent material and lengths from the installation manual before any vent work.

Fault codes documented for this model

None documented yet.

Services

Hot water and scalding

  1. Water above 49 °C at a tap can scald in seconds, and children and older adults are at most risk. BC's plumbing code limits shower and bathtub water to 49 °C.
  2. Storage tanks are normally kept hotter (Health Canada advises 60 °C) to limit Legionella growth, with a thermostatic mixing valve tempering the water to the fixtures.
  3. Never bypass or remove a mixing valve, thermostat or high-limit control to get hotter water.

Official guidance: Government of Canada on water temperature and scalds and HealthLinkBC.

Frequently asked questions

Is the NPE-240A2 sold in Canada?

Yes. Navien's Canadian site lists the NPE-A2 series with the NPE-240A2 among its residential water heaters.

How much hot water can it deliver in winter?

At a 67 °F (37 °C) rise Navien rates it at 5.6 GPM (21.2 L/min), which is the winter-class figure for Metro Vancouver; two showers at once are assessed against that, not against the 11.2 GPM 35 °F figure.

What is the difference between the NPE-A2 and NPE-S2?

The NPE-S2 is the newer series Navien lists alongside the A2. This page documents the A2 platform; the S2 models are catalogued separately when published.

Questions about the Navien NPE-240A2?

Describe what the water heater is doing and get a straight answer about the next step.

On-site service in Metro Vancouver, BC. Call to check availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.