Navien NPE-240A2 vs NPE-180A2: Largest or Smallest A2?

Verdict in brief

Both are wall-hung, forced-draft direct-vent condensing tankless units from Navien's Canadian A2 platform with UEF 0.95, the same 27.4 in cabinet and the same 2 in or 3 in PVC-family venting. The NPE-240A2 is 13,300–199,900 BTU/h and the NPE-180A2 is 10,000–150,000 BTU/h. Navien publishes flow at three rises, and at the 67 °F figure closest to a Metro Vancouver winter the pair delivers 5.6 GPM against 4.3 GPM: the 180A2 is a one-fixture-at-a-time unit in January, and the 240A2 is marginal for two. Choose by peak simultaneous demand, not by house size.

Side by side

Published manufacturer figures with units. Storage and flow figures are different measures and are shown on their own rows; blanks mean not applicable or not published.

Comparison of Navien NPE-240A2 and Navien NPE-180A2
SpecificationNavien NPE-240A2Gas tanklessNavien NPE-180A2Gas tankless
Minimum gas input13,300 BTU/h10,000 BTU/h
Maximum gas input199,900 BTU/h150,000 BTU/h
Flow at a 35 °F (19.4 °C) rise11.2 GPM (42.4 L/min) at 35 °F (19.4 °C) rise8.4 GPM (31.8 L/min) at 35 °F (19.4 °C) rise
Flow at a 45 °F (25 °C) rise8.7 GPM (32.9 L/min) at 45 °F (25 °C) rise6.5 GPM (24.6 L/min) at 45 °F (25 °C) rise
Flow at a 67 °F (37.2 °C) rise5.6 GPM (21.2 L/min) at 67 °F (37.2 °C) rise4.3 GPM (16.3 L/min) at 67 °F (37.2 °C) rise
Minimum flow rate0.5 GPM (1.9 L/min); under 0.01 GPM option in ComfortFlow mode0.5 GPM (1.9 L/min); under 0.01 GPM option in ComfortFlow mode
Uniform Energy Factor (UEF)0.950.95
Vent type2 in or 3 in PVC, CPVC, approved polypropylene or stainless steel; special gas vent type BH (Class II A/B/C)2 in or 3 in PVC, CPVC, approved polypropylene or stainless steel; special gas vent type BH (Class II A/B/C)
Gas connection3/4 in3/4 in
Water connections3/4 in cold inlet and hot outlet3/4 in cold inlet and hot outlet
Electrical supply120 V AC, 60 Hz; up to 200 W (2 A), 350 W (4 A) with external pump120 V AC, 60 Hz; up to 200 W (2 A), 350 W (4 A) with external pump
Height27.4 in (696 mm)27.4 in (696 mm)
Width17.3 in (439 mm)17.3 in (439 mm)
Depth13.2 in (335 mm)13.2 in (335 mm)
Weight77 lb (34.9 kg)73 lb (33.1 kg)
Maximum altitude10,100 ft for natural gas and propane10,100 ft for natural gas and propane

“—” means not applicable to that system type or not published by the manufacturer. Flow figures are only comparable at the same temperature rise; UEF values are only comparable within the same draw pattern.

What actually separates them

Navien's at-rise flow table makes this comparison unusually honest. At a 35 °F (19.4 °C) rise the NPE-240A2 delivers 11.2 GPM (42.4 L/min) and the NPE-180A2 8.4 GPM (31.8 L/min); at 45 °F (25 °C) it is 8.7 against 6.5 GPM; and at 67 °F (37.2 °C) it is 5.6 GPM (21.2 L/min) against 4.3 GPM (16.3 L/min). Because heating Metro Vancouver's winter inlet water to a 49 °C shower is roughly a 40 °C (72 °F) rise, the 67 °F row is the one that decides whether a second shower can run alongside the first.

Input and modulation track the size gap. The NPE-240A2 modulates from 13,300 to 199,900 BTU/h; the NPE-180A2 from 10,000 to 150,000 BTU/h. The smaller unit therefore turns down lower for a single low-flow tap but tops out 49,900 BTU/h sooner. The NPE-240A2 is also the heavier cabinet at 77 lb (34.9 kg) against 73 lb (33.1 kg), though both share the same 27.4 in × 17.3 in × 13.2 in dimensions.

Everything else in the platform is common: UEF 0.95 on natural gas and propane, 3/4 in gas and water connections, 120 V power drawing up to 200 W (350 W with an external pump), the same 2 in or 3 in PVC, CPVC, approved polypropylene or stainless venting (or BH special gas vent) terminated as a forced-draft direct vent with zero clearance to combustibles, a condensate drain, and ComfortFlow recirculation through an external pump or crossover valve rather than a built-in pump. Both are rated to 10,100 ft altitude and both are subject to Navien's published policy voiding warranty on internet or e-commerce purchases.

The middle NPE-210A2 sits between them and is documented separately. In practice a one-bathroom home or suite with sequential use fits the NPE-180A2; a two-bathroom home that expects occasional overlap in January should start from the NPE-210A2 or NPE-240A2 rather than the entry size. A demand assessment measures simultaneous flow and confirms the gas supply and vent route before a model is specified, and whether CANRO supplies a given A2 model for a job is confirmed at consultation.

Navien · Gas tankless

Navien NPE-240A2

CurrentSold in Canada
Max input
199,900 BTU/h
Flow at 35 °F (19.4 °C) rise
11.2 GPM (42.4 L/min)
Uniform Energy Factor (UEF)
0.95

The Navien NPE-240A2 is the largest of Navien's Canadian A2 condensing tankless models: 13,300–199,900 BTU/h on natural gas or propane, UEF 0.95, and published flows of 11.2 GPM at a 35 °F rise and 5.6 GPM at a 67 °F rise. It is a wall-hung, forced-draft direct-vent unit.

Natural gasPropaneCondensing, PVC/CPVC/PP

Navien · Gas tankless

Navien NPE-180A2

CurrentSold in Canada
Max input
150,000 BTU/h
Flow at 35 °F (19.4 °C) rise
8.4 GPM (31.8 L/min)
Uniform Energy Factor (UEF)
0.95

The Navien NPE-180A2 is the smallest of Navien's Canadian A2 condensing tankless models: 10,000–150,000 BTU/h on natural gas or propane, UEF 0.95, and published flows of 8.4 GPM at a 35 °F rise and 4.3 GPM at a 67 °F rise. It is a wall-hung, forced-draft direct-vent unit.

Natural gasPropaneCondensing, PVC/CPVC/PP

Frequently asked questions

Is the NPE-240A2 twice the water heater of the NPE-180A2?

No. It is 33% more input (199,900 against 150,000 BTU/h) and 30% more flow at the winter-class rise (5.6 against 4.3 GPM at 67 °F). It buys simultaneous capacity, not more hot water for a single fixture.

Can the NPE-180A2 serve a two-bathroom home?

Only if the bathrooms are used sequentially. At its published 67 °F-rise rating of 4.3 GPM it cannot carry two shower-class fixtures at once in a Metro Vancouver winter; overlapping use points to the NPE-210A2 or NPE-240A2.

Do they need different venting or gas lines?

No. Both use the A2 platform's 2 in or 3 in PVC, CPVC, approved polypropylene or stainless venting (or BH special gas vent), a 3/4 in gas connection and a 120 V outlet, with a condensate drain for the acidic condensate.

Not sure which one fits your home?

A consultation includes a hot-water demand review so capacity is right for your winter, not the brochure's.

On-site service in Metro Vancouver, BC. Call to check availability.

Sources and verification

Facts checked September 21, 2026. Last updated September 21, 2026. Technical reviewer: not yet assigned.

Call 604-359-1081Get Estimate