Skip to content
WaterHeating.caby CANRO Heating & Cooling

Bradford White · Defender Safety System atmospheric vent (RG2) · Gas storage tank

Bradford White RG230S6N

The Bradford White RG230S6N is a 30 US gallon (114 L) short-form atmospheric-vent natural gas storage water heater with a 30,000 BTU/h input, 49 US gallon first-hour rating and UEF 0.54, sold in Canada through wholesale channels. It fits under low ceilings where even a tall 30-gallon tank will not.

CurrentSold in Canada

Key figures

Nominal capacity
30 US gal (25 Imp. gal, 114 L)
First-hour delivery
49 US gal (185 L)
Input
30,000 BTU/h
Uniform Energy Factor (UEF), medium draw
0.54
Natural gasPropaneAtmospheric (draft hood)residential

Nominal volume, rated volume and first-hour delivery are different figures; size by first-hour delivery.

Bradford White RG230S6N in practice

The RG230S6N is the shortest Defender atmospheric tank on the Canadian sheet: 45 3/4 in (1162 mm) to the top of the heater, about 10 1/2 in shorter than the tall RG230T6N, with a 20 in (508 mm) jacket. It pairs a 30,000 BTU/h natural gas input with a first-hour rating of 49 US gallons (185 L), which suits one or two people whose space, not whose demand, forced the choice of a small short tank.

It vents by natural draft through a 3" or 4" draft hood, draws combustion air from the room and needs no electricity. Unlike the rest of the line it has no optional top temperature-and-pressure valve location. UEF 0.54 is the lowest rating on the Canadian atmospheric sheet and is below ENERGY STAR. Whether CANRO stocks this model for a given job is confirmed at consultation.

Best suited to

  • Very low basement ceilings, under-stair closets and crawl spaces with a chimney connection
  • Like-for-like replacement of an existing short 30 US gal atmospheric gas tank
  • One- or two-person households with modest peak-hour demand

Limitations to know

  • 49 US gal first-hour delivery is the lowest of the Defender atmospheric line
  • No optional top T&P valve location on the short 30-gallon form
  • UEF 0.54 is below ENERGY STAR; a power-vent, condensing tank or tankless unit is more efficient
  • Warranty excludes labour and anode consumption; anode inspection every 2 years is required

Applicability and support

Model number
RG230S6N
Variants on this page
RG230S6X (Propane, 26,000 BTU/h); RG230S10N (10-year warranty version)
Canadian availability
available
Production status
current
CANRO supplies
Confirmed at consultation
CANRO services
Confirmed at consultation
Recirculation
Not published
Warranty
Series terms

Storage tanks can serve a recirculation loop with an external pump and return connection; Bradford White does not publish recirculation guidance for this model, so any loop is designed at consultation.

Where CANRO provides on-site service

On-site service is currently offered across Metro Vancouver: Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Delta, Langley, Port Moody, Port Coquitlam, Maple Ridge, Pitt Meadows, White Rock, Tsawwassen; plus Anmore, Belcarra, Lions Bay, Bowen Island, Abbotsford with travel or ferry arrangements confirmed by phone. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Bradford White. Manufacturer gallon and BTU/h figures are preserved with metric alongside; notes flag conflicting documents and missing figures. Groups expand for detail.

Storage capacity 2
Bradford White RG230S6N specifications: Storage capacity
SpecificationValueNote
Rated nominal volume30 US gal (25 Imp. gal, 114 L)Canadian sheet C1101. Nominal, not the tested storage volume.
Rated (DOE) storage volume29 US gal (110 L)Published on the US sheet 1101 only; not on the Canadian sheet.
Delivery and recovery 2
Bradford White RG230S6N specifications: Delivery and recovery
SpecificationValueNote
First-hour rating49 US gal (185 L)Single column on C1101, not fuel-specific. Based on AHRI directory listing.
Recovery at 90 °F (50 °C) rise, natural gas32 US gal/h (27 Imp. gal/h, 121 L/h)Recovery efficiency up to 80% per Bradford White.
Input 2
Bradford White RG230S6N specifications: Input
SpecificationValueNote
Input, natural gas30,000 BTU/h8.8 kW.
Input, propane (RG230S6X)26,000 BTU/h7.6 kW.
Efficiency 1
Bradford White RG230S6N specifications: Efficiency
SpecificationValueNote
Uniform Energy Factor (UEF), medium draw0.54Per AHRI listing cited on C1101. Not ENERGY STAR (v5.0 requires UEF ≥ 0.81 for this size).
Venting and air 1
Bradford White RG230S6N specifications: Venting and air
SpecificationValueNote
Vent connection3 in or 4 in (76 or 102 mm) draft hood"Snap Lock" 3x4 draft diverter; atmospheric venting into a suitable chimney or B-vent.
Connections 3
Bradford White RG230S6N specifications: Connections
SpecificationValueNote
Water connections3/4 in NPT with dielectric waterways and heat traps
Gas connection1/2 in (13 mm)
T&P relief valveFactory installed; no top location optionThe short 30-gallon model does not offer the optional top T&P location.
Electrical 1
Bradford White RG230S6N specifications: Electrical
SpecificationValueNote
Electrical supplyNone required (ICON System control powered by the pilot thermopile)
Physical 3
Bradford White RG230S6N specifications: Physical
SpecificationValueNote
Height to top of heater45 3/4 in (1162 mm)49 1/4 in (1251 mm) to the exhaust connection.
Jacket diameter20 in (508 mm)Depth 23 1/2 in (597 mm) including fittings.
Shipping weight113 lb (51 kg)
Operating limits 2
Bradford White RG230S6N specifications: Operating limits
SpecificationValueNote
Working pressure150 psi (1034 kPa); tested at 300 psi (2068 kPa)
CertificationCSA International, ANSI Z21.10.1 / CSA 4.1
Other 1
Bradford White RG230S6N specifications: Other
SpecificationValueNote
Anode rodMagnesium, combined with the hot-water outlet nippleAluminum options listed in the Canadian parts list.

Manuals

Maintenance the manufacturer specifies

  • Inspect the anode rod every 2 years and replace when depleted; more often with softened water (manual, Maintenance item 9).
  • Operate the T&P relief valve at least once a year to check it lifts and reseats without leaking (item 6).
  • Drain about a gallon monthly to remove sediment (item 7); annual inspection by a qualified technician.
  • Inspect the vent system at least once a year; check burner flames twice a year (items 10 and 4).

Fault codes documented for this model

Services

Hot water and scalding

  1. Water above 49 °C at a tap can scald in seconds, and children and older adults are at most risk. BC's plumbing code limits shower and bathtub water to 49 °C.
  2. Storage tanks are normally kept hotter (Health Canada advises 60 °C) to limit Legionella growth, with a thermostatic mixing valve tempering the water to the fixtures.
  3. Never bypass or remove a mixing valve, thermostat or high-limit control to get hotter water.

Official guidance: Government of Canada on water temperature and scalds and HealthLinkBC.

Frequently asked questions

Is the RG230S6N sold in Canada?

Yes. It is listed on Bradford White's Canadian residential gas page and on Canadian spec sheet C1101. Bradford White sells only through wholesalers, so it is supplied and installed by contractors such as CANRO.

What is the difference between the RG230S6N and the RG230T6N?

The S denotes the short form: about 10 1/2 in (267 mm) shorter with a wider 20 in jacket, a 30,000 rather than 32,000 BTU/h input, and a 49 rather than 60 US gallon first-hour rating.

Can the RG230S6N run on propane?

The propane version is the RG230S6X with a 26,000 BTU/h input per the Canadian sheet. Fuel conversion is not a field procedure on this model; order the correct fuel version.

Questions about the Bradford White RG230S6N?

Describe what the water heater is doing and get a straight answer about the next step.

On-site service in Metro Vancouver, BC. Call to check availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

Call 604-359-1081Get Estimate