Giant · Residential gas storage tanks · Gas storage tank

Giant UG50-62 power-vent

The Giant UG50-62 is a 50 US gallon (189 L) power-vent natural gas or propane storage water heater with a 62,000 BTU/h input, a motorized blower for side-wall venting, 3/4 in side taps and a 6-year tank and parts warranty, made in Canada by Giant.

CurrentSold in Canada

Key figures

Nominal capacity
50 US gal (189 L)
First-hour delivery
Input
Efficiency
Natural gasPropanePower ventresidential

Nominal volume, rated volume and first-hour delivery are different figures; size by first-hour delivery.

Giant UG50-62 power-vent in practice

The Giant UG50-62 is the high-input 50-gallon member of Giant's Canadian power-vent residential gas storage line, at 50 US gallons (189 L) with a 62,000 BTU/h input on both natural gas and propane. Unlike an atmospheric tank, a power-vent model draws combustion air from inside the home and uses a motorized blower to force the exhaust outside through 2 in, 3 in or 4 in ULC S636 PVC, CPVC or polypropylene pipe up to 180 equivalent feet, horizontally or vertically, so it does not need a chimney. Giant lists a 3-position rotatable blower for flexible installation, a TankSaver design, a flammable-vapour sensor that shuts the unit down, an air-intake snorkel, a glass-lined inner tank, a magnesium anode and an electronic gas control valve with self-diagnostic capability.

Giant's page gives storage capacity and input but does not publish a first-hour rating, recovery rate, energy factor or dimensions for this model, so WaterHeating.ca does not state those figures. The published warranty is 6 years against inner tank leakage and 6 years on component parts from the date of installation, with conditions in the owner's manual. The 3/4 in side taps on the 50-62 high-input model suit combination applications.

A power-vent unit needs a 120 V supply for the blower and a sealed side-wall vent route, so it is the family to consider where no usable chimney exists or a mechanical room is sealed. The installation manual governs the approved vent materials, lengths and clearances. Whether CANRO supplies this model for a given job is confirmed at consultation.

Best suited to

  • Replacing a tank where no usable chimney exists and side-wall venting is required
  • Households that want a higher recovery rate than an atmospheric 40-gallon tank
  • Combination applications that use the 3/4 in side taps on the high-input model

Limitations to know

  • Requires electrical power for the blower; no hot water during an outage
  • Needs a sealed vent route to an exterior termination; the manual governs materials and lengths
  • Giant does not publish a first-hour rating or energy factor for this model, so sizing is confirmed in a demand assessment
  • Warranty excludes labour and anode consumption; anode inspection is required

Applicability and support

Model number
UG50-62
Variants on this page
UG50-62 (LP) (Propane)
Canadian availability
available
Production status
current
CANRO supplies
Confirmed at consultation
CANRO services
Confirmed at consultation
Recirculation
Not published
Warranty
Series terms

Storage tanks can serve a recirculation loop with an external pump and return connection; Giant does not publish recirculation guidance for this model, so any loop is designed at consultation.

Where CANRO provides on-site service

On-site service is currently offered across Metro Vancouver: Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Delta, Langley, Port Moody, Port Coquitlam, Maple Ridge, Pitt Meadows, White Rock, Tsawwassen; plus Anmore, Belcarra, Lions Bay, Bowen Island, Abbotsford with travel or ferry arrangements confirmed by phone. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Giant. Manufacturer gallon and BTU/h figures are preserved with metric alongside; notes flag conflicting documents and missing figures. Groups expand for detail.

Storage capacity 1
Giant UG50-62 power-vent specifications: Storage capacity
SpecificationValueNote
Storage capacity50 US gal (189 L)Giant lists US gallons on the Canadian product page; the figure is the nominal tank volume, not a first-hour rating.
Input 1
Giant UG50-62 power-vent specifications: Input
SpecificationValueNote
Input, natural gas62,000 BTU/h18.2 kW. Giant lists the same input for the propane version.
Venting and air 1
Giant UG50-62 power-vent specifications: Venting and air
SpecificationValueNote
Venting2 in, 3 in or 4 in ULC S636 PVC, CPVC or polypropylene, horizontal or vertical, up to 180 equivalent feetThe UG50-62 high-input model is listed in 3 in or 4 in venting. The installation manual governs approved materials and lengths.
Connections 1
Giant UG50-62 power-vent specifications: Connections
SpecificationValueNote
Side taps3/4 in side taps for combination applications on 50-62 high-input modelsGiant lists side taps on the high-input 50-62 model.
Operating limits 1
Giant UG50-62 power-vent specifications: Operating limits
SpecificationValueNote
CertificationCSA reference published by Giant; EnerGuide referenced on the same pageReproduced from Giant's Canadian page; the rating plate governs the installed unit.
Other 2
Giant UG50-62 power-vent specifications: Other
SpecificationValueNote
Type of gasNatural gas (N) or propane (LP)Giant lists both fuels for the UG50-62.
Warranty (Giant published)6 years against inner tank leakage; 6 years on component parts, from the date of installationGiant states certain conditions apply and the owner's manual carries the exceptions.

Manuals

Maintenance the manufacturer specifies

  • Giant lists a top-mounted heavy-duty magnesium anode rod and a TankSaver design; inspect and replace the anode as the installation manual directs.
  • Giant lists a state-of-the-art electronic gas control valve with self-diagnostic capability; the installation manual governs vent, blower and flame inspection intervals.

Fault codes documented for this model

None documented yet.

Services

Hot water and scalding

  1. Water above 49 °C at a tap can scald in seconds, and children and older adults are at most risk. BC's plumbing code limits shower and bathtub water to 49 °C.
  2. Storage tanks are normally kept hotter (Health Canada advises 60 °C) to limit Legionella growth, with a thermostatic mixing valve tempering the water to the fixtures.
  3. Never bypass or remove a mixing valve, thermostat or high-limit control to get hotter water.

Official guidance: Government of Canada on water temperature and scalds and HealthLinkBC.

Frequently asked questions

Is the Giant UG50-62 sold in Canada?

Yes. It is listed on Giant's Canadian residential gas pages (giantinc.com) under power vent, with a Canadian specification sheet, installation manual and parts list linked from the product page.

What is the difference between the UG50 and the UG50-62?

Giant lists both as 50 US gallon power-vent models; the UG50-62 is the high-input version at 62,000 BTU/h with 3/4 in side taps, listed in 3 in or 4 in venting, while the standard UG50 is listed at 32,000 BTU/h in 2 in, 3 in or 4 in venting.

Does the Giant UG50-62 need a chimney?

No. A power-vent model forces the exhaust outside with a motorized blower through ULC S636 PVC, CPVC or polypropylene pipe, so it does not need a chimney. It does need a sealed vent route to an exterior termination and electrical power for the blower.

Can the Giant UG50-62 run on propane?

Yes. Giant lists the UG50-62 for natural gas (N) and propane (LP) with the same 62,000 BTU/h input for both. Fuel conversion is not a field procedure on this model; order the correct fuel version.