Skip to content
WaterHeating.caby CANRO Heating & Cooling

Bradford White · Upright electric (RE2) · Electric storage tank

Bradford White RE240S6

The Bradford White RE240S6 is a 38 US gallon (144 L) short-form electric storage water heater with two 4,500 W elements, a 55 US gallon first-hour rating and a 61 W standby-loss rating, sold in Canada through wholesale channels. It needs no venting or gas line.

CurrentSold in Canada

Key figures

Nominal capacity
38 US gal (32 Imp. gal, 144 L)
First-hour delivery
55 US gal (208 L)
Efficiency
ElectricNo venting (electric)residential

Nominal volume, rated volume and first-hour delivery are different figures; size by first-hour delivery.

Bradford White RE240S6 in practice

The RE240S6 is the short 40-class member of the Canadian RE2 upright electric family: 47 3/16 in (1199 mm) to the top of the heater in a 20 in (508 mm) jacket. Its 55 US gallon (208 L) first-hour rating at the standard 4,500 W two-element configuration reflects the slow recovery of electric heating, so the stored volume does more of the work than on a gas tank of similar size.

It needs no venting, gas line or combustion air, but it does need a dedicated 240 V circuit, and BC's plumbing code sets electric storage thermostats at 60 °C with a mixing valve limiting fixtures to 49 °C. The Canadian sheet rates the model by a 61 W standby loss rather than a UEF, which is the honest comparison figure between electric tanks. Whether CANRO stocks this model for a given job is confirmed at consultation.

Best suited to

  • Homes, condos and suites without gas service that need a compact 40-class electric tank
  • Low-ceiling spaces where the short form fits
  • Like-for-like replacement of an existing electric tank on the same circuit

Limitations to know

  • Slow recovery: the first-hour rating leans on stored volume, so peaks need a bigger tank than with gas
  • Requires a dedicated 240 V circuit; no hot water during a power outage
  • Electricity cost per litre of hot water is typically higher than gas in BC
  • Warranty excludes labour and anode consumption; anode inspection every 2 years is required

Applicability and support

Model number
RE240S6
Variants on this page
RE240S10 (10-year warranty version)
Canadian availability
available
Production status
current
CANRO supplies
Confirmed at consultation
CANRO services
Confirmed at consultation
Recirculation
Not published
Warranty
Series terms

Storage tanks can serve a recirculation loop with an external pump and return connection; Bradford White does not publish recirculation guidance for this model, so any loop is designed at consultation.

Where CANRO provides on-site service

On-site service is currently offered across Metro Vancouver: Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Delta, Langley, Port Moody, Port Coquitlam, Maple Ridge, Pitt Meadows, White Rock, Tsawwassen; plus Anmore, Belcarra, Lions Bay, Bowen Island, Abbotsford with travel or ferry arrangements confirmed by phone. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Bradford White. Manufacturer gallon and BTU/h figures are preserved with metric alongside; notes flag conflicting documents and missing figures. Groups expand for detail.

Storage capacity 1
Bradford White RE240S6 specifications: Storage capacity
SpecificationValueNote
Rated nominal capacity38 US gal (32 Imp. gal, 144 L)Canadian sheet C1201. Nominal, not the tested storage volume.
Delivery and recovery 2
Bradford White RE240S6 specifications: Delivery and recovery
SpecificationValueNote
First-hour rating55 US gal (208 L)Single column on C1201. Based on the sheet's rating.
Recovery at 90 °F (50 °C) rise21 US gal/h (18 Imp. gal/h, 79 L/h)At the standard 4,500 W element configuration (non-simultaneous operation).
Efficiency 1
Bradford White RE240S6 specifications: Efficiency
SpecificationValueNote
Standby loss61 WCanadian electric tanks are rated by standby loss in watts rather than UEF; the figure is not comparable with a gas tank's UEF.
Connections 2
Bradford White RE240S6 specifications: Connections
SpecificationValueNote
Water connections3/4 in NPTElectrical connection is also 3/4 in NPT conduit per the sheet.
T&P relief valveFactory installed
Electrical 2
Bradford White RE240S6 specifications: Electrical
SpecificationValueNote
ElementsTwo 4,500 W elements, wired non-simultaneous (interlocking), unless otherwise specifiedPer the Canadian sheet's general notes; element wattage options run from 1,500 W to 6,000 W at other voltages.
Electrical supply240 V, single phase, 60 Hz; dedicated circuitThe sheet's element table also lists 120–480 V options; a 240 V supply is the standard wiring.
Physical 3
Bradford White RE240S6 specifications: Physical
SpecificationValueNote
Height to top of heater47 3/16 in (1199 mm)Short form.
Jacket diameter20 in (508 mm)
Shipping weight123 lb (56 kg)
Operating limits 2
Bradford White RE240S6 specifications: Operating limits
SpecificationValueNote
Working pressure150 psi (1034 kPa); tested at 300 psi (2068 kPa)
CertificationUL listed
Other 1
Bradford White RE240S6 specifications: Other
SpecificationValueNote
Anode rodMagnesium, combined with the hot-water outlet nipple

Manuals

Maintenance the manufacturer specifies

  • Inspect the anode rod every 2 years and replace when depleted; more often with softened water.
  • Operate the T&P relief valve at least once a year to check it lifts and reseats without leaking.
  • Drain about a gallon monthly to remove sediment; annual inspection by a qualified technician.
  • Have a technician test the elements and thermostats when heating is slow or the tank runs out early.

Fault codes documented for this model

None documented yet.

Services

Hot water and scalding

  1. Water above 49 °C at a tap can scald in seconds, and children and older adults are at most risk. BC's plumbing code limits shower and bathtub water to 49 °C.
  2. Storage tanks are normally kept hotter (Health Canada advises 60 °C) to limit Legionella growth, with a thermostatic mixing valve tempering the water to the fixtures.
  3. Never bypass or remove a mixing valve, thermostat or high-limit control to get hotter water.

Official guidance: Government of Canada on water temperature and scalds and HealthLinkBC.

Frequently asked questions

Is the RE240S6 sold in Canada?

Yes. It is listed on Bradford White's Canadian electric range and on Canadian spec sheet C1201. Bradford White sells only through wholesalers, so it is supplied and installed by contractors such as CANRO.

What electrical supply does it need?

A dedicated 240 V circuit. The sheet's default wiring is two 4,500 W elements wired non-simultaneous at 240 V, single phase; other element and voltage options are listed on the sheet.

Can the RE240S6 replace a gas tank?

Physically, where a 240 V circuit exists and the venting is abandoned, but the slower recovery and higher operating cost make it a demand and budget decision, not a swap.

Questions about the Bradford White RE240S6?

Describe what the water heater is doing and get a straight answer about the next step.

On-site service in Metro Vancouver, BC. Call to check availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

Call 604-359-1081Get Estimate