Navien NPE-150S2

The Navien NPE-150S2 is the smallest of Navien's current S2 condensing tankless models: 18,000–120,000 BTU/h on natural gas or propane, UEF 0.93, and published flows of 6.8 GPM at a 35 °F rise and 3.4 GPM at a 67 °F rise.

CurrentSold in Canada

Key figures

Max input
120,000 BTU/h
Flow at 35 °F (19.4 °C) rise
6.8 GPM (25.7 L/min)
Uniform Energy Factor (UEF)
0.93
Natural gasPropaneCondensing, PVC/CPVC/PPresidential

Flow figures depend on temperature rise; compare only at the same rise. Max flow is not guaranteed winter performance.

Navien NPE-150S2 in practice

The NPE-150S2 is the entry size of Navien's current S2 platform, suited to a suite, laneway home or small house whose peak demand fits a 120,000 BTU/h input: Navien rates it at 6.8 GPM (25.7 L/min) at a 35 °F rise and 3.4 GPM (12.9 L/min) at a 67 °F rise, with UEF 0.93 against the 0.96 of the larger S2 sizes. Because the Metro Vancouver winter rise to a 49 °C shower approaches 40 °C (72 °F), the winter-class figure makes this a one-fixture-at-a-time unit in January.

It shares the S2 cabinet (17.3 in wide, 27.4 in high, 13.2 in deep) at the lightest weight in the series, 62 lb (28.1 kg), with forced-draft direct venting, 3/4 in connections and 120 V operation. Navien's page marks this model not ENERGY STAR certified. Whether CANRO stocks this model for a given job is confirmed at consultation.

Best suited to

  • Suites, laneway homes and one-bathroom houses with sequential demand
  • Small homes wanting a current-generation condensing unit at the lowest S2 input
  • Conversions where the gas supply and vent route suit 120,000 BTU/h

Limitations to know

  • Winter delivery at a 67 °F-class rise is 3.4 GPM: one fixture at a time in January
  • UEF 0.93 and not ENERGY STAR certified on Navien's page
  • Requires 120 V power; no hot water during an outage
  • Needs a sealed 2 in or 3 in vent route and a condensate drain
  • Navien's published resale policy voids warranty for internet or e-commerce purchases; supply runs through contractors

Applicability and support

Model number
NPE-150S2
Variants on this page
None
Canadian availability
available
Production status
current
CANRO supplies
Confirmed at consultation
CANRO services
Confirmed at consultation
Recirculation
Yes, external pump and piping required
Warranty
Not verified

The S2 platform supports Navien's recirculation configuration with an external pump or crossover accessory; energy consumption rises when recirculation is configured. Recirculation shortens, not eliminates, the wait at the tap.

Where CANRO provides on-site service

On-site service is currently offered across Metro Vancouver: Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Delta, Langley, Port Moody, Port Coquitlam, Maple Ridge, Pitt Meadows, White Rock, Tsawwassen; plus Anmore, Belcarra, Lions Bay, Bowen Island, Abbotsford with travel or ferry arrangements confirmed by phone. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Navien. Manufacturer gallon and BTU/h figures are preserved with metric alongside; notes flag conflicting documents and missing figures. Groups expand for detail.

Flow (tankless) 4
Navien NPE-150S2 specifications: Flow (tankless)
SpecificationValueNote
Flow at a 35 °F (19.4 °C) rise6.8 GPM (25.7 L/min) at 35 °F (19.4 °C) riseNavien's published rating table.
Flow at a 45 °F (25 °C) rise5.3 GPM (20.1 L/min) at 45 °F (25 °C) riseNavien's published rating table.
Flow at a 67 °F (37.2 °C) rise3.4 GPM (12.9 L/min) at 67 °F (37.2 °C) riseNavien's published rating table; the winter rise in Metro Vancouver is in this range.
Minimum flow rate0.5 GPM (1.9 L/min)Per Navien's specification table.
Input 2
Navien NPE-150S2 specifications: Input
SpecificationValueNote
Minimum gas input18,000 BTU/h5.27 kW. Natural gas and propane per Navien.
Maximum gas input120,000 BTU/h35.16 kW. Natural gas and propane per Navien.
Efficiency 1
Navien NPE-150S2 specifications: Efficiency
SpecificationValueNote
Uniform Energy Factor (UEF)0.93Natural gas and propane per Navien's specification table. Navien's page marks this model not ENERGY STAR certified.
Venting and air 1
Navien NPE-150S2 specifications: Venting and air
SpecificationValueNote
Vent type2 in or 3 in PVC, CPVC, approved polypropylene or stainless steel; special gas vent type BH (Class II A/B/C)Forced-draft direct vent per Navien; zero clearance to combustibles.
Connections 2
Navien NPE-150S2 specifications: Connections
SpecificationValueNote
Gas connection3/4 inNG supply pressure 3.5–10.5 in. w.c.; propane 8–13 in. w.c.
Water connections3/4 in cold inlet and hot outlet
Electrical 1
Navien NPE-150S2 specifications: Electrical
SpecificationValueNote
Electrical supply120 V AC, 60 Hz; up to 200 W (2 A), 350 W (4 A) with external pump
Physical 4
Navien NPE-150S2 specifications: Physical
SpecificationValueNote
Height27.4 in (696 mm)
Width17.3 in (439 mm)
Depth13.2 in (335 mm)
Weight62 lb (28.1 kg)
Operating limits 2
Navien NPE-150S2 specifications: Operating limits
SpecificationValueNote
Maximum altitude10,100 ft for natural gas and propanePer Navien; the installation manual has the details.
Safety devicesFlame rod, air-pressure switch, ignition-operation detector and high-limit devices per Navien's specification table

Manuals

Maintenance the manufacturer specifies

  • Flush (descale) the heat exchanger periodically per Navien's maintenance guidance; scale damage is not covered by warranty.
  • Clean the water inlet filter as part of the service interval.
  • Check the condensate drain and trap for flow and blockage at service.
  • Confirm the correct vent material and lengths from the installation manual before any vent work.

Fault codes documented for this model

None documented yet.

Services

Hot water and scalding

  1. Water above 49 °C at a tap can scald in seconds, and children and older adults are at most risk. BC's plumbing code limits shower and bathtub water to 49 °C.
  2. Storage tanks are normally kept hotter (Health Canada advises 60 °C) to limit Legionella growth, with a thermostatic mixing valve tempering the water to the fixtures.
  3. Never bypass or remove a mixing valve, thermostat or high-limit control to get hotter water.

Official guidance: Government of Canada on water temperature and scalds and HealthLinkBC.

Frequently asked questions

Is the NPE-150S2 sold in Canada?

Yes. Navien's Canadian product listing shows the NPE-150S2 among the NPE-S2 series residential water heaters.

How does the NPE-150S2 compare with the NPE-180S2?

It is capped at 120,000 BTU/h against the NPE-180S2's 150,000, with lower flow at each published rise (6.8 GPM against 8.4 GPM at a 35 °F rise) and UEF 0.93 against 0.96. It is the smaller, lighter entry model.

Can the NPE-150S2 run two showers in winter?

At its 67 °F-rise rating of 3.4 GPM it cannot serve two shower-class fixtures at once in January; the honest option for that demand is a larger S2 model or a demand assessment.

Questions about the Navien NPE-150S2?

Describe what the water heater is doing and get a straight answer about the next step.

On-site service in Metro Vancouver, BC. Call to check availability.

Sources and verification

Facts checked September 19, 2026. Last updated September 19, 2026. Technical reviewer: not yet assigned.

Call 604-359-1081Get Estimate