Bradford White RG2DV40S6N

The Bradford White RG2DV40S6N is a 40 US gallon (151 L) direct vent natural gas storage water heater with a 38,000 BTU/h input, 62 US gallon first-hour rating and UEF 0.60, sold in Canada through wholesale channels. Its sealed co-axial vent needs no chimney and no electricity.

CurrentSold in Canada

Key figures

Nominal capacity
40 US gal (33 Imp. gal, 151 L)
First-hour delivery
62 US gal (235 L)
Input
38,000 BTU/h
Uniform Energy Factor (UEF), medium draw
0.6
Natural gasPropaneDirect ventresidential

Nominal volume, rated volume and first-hour delivery are different figures; size by first-hour delivery.

Bradford White RG2DV40S6N in practice

The RG2DV40S6N is the 40-gallon member of Bradford White's Canadian direct vent line, built for homes where an atmospheric tank's chimney is gone but a power vent's blower and wiring are unwanted. Combustion air comes down the outer pipe of the 3 in x 5 in co-axial vent while exhaust leaves through the inner pipe, so the heater is sealed from the room and the millivolt ICON control needs no power at all.

The trade is the vent: it must terminate through a side wall with the manufacturer's telescoping or flexible kits (solid kits cover up to 8 ft of run, the flexible kit reaches 100 in), which fixes where in the room the tank can sit. The sheet gives a minimum of 63 1/2 in from the floor to the vent centre-line. UEF 0.60 is a medium-draw rating below ENERGY STAR, and the sheet states 78% recovery efficiency for the family. Whether CANRO stocks this model for a given job is confirmed at consultation.

Best suited to

  • Homes without a chimney where a side-wall vent termination is possible
  • Buyers who want a gas tank that keeps working during power outages but cannot use an atmospheric unit
  • Like-for-like replacement of an existing direct vent tank with a serviceable vent kit

Limitations to know

  • Vent must use the manufacturer's co-axial kits and a side-wall termination within the kit's run limits
  • 62 US gal first-hour rating is the lowest of the direct vent family
  • UEF 0.60 is below ENERGY STAR; a condensing tank or tankless unit is more efficient
  • Warranty excludes labour and anode consumption; anode inspection every 2 years is required

Applicability and support

Model number
RG2DV40S6N
Variants on this page
RG2DV40S6X (Propane, 36,000 BTU/h); RG2DV40S10N (10-year warranty version)
Canadian availability
available
Production status
current
CANRO supplies
Confirmed at consultation
CANRO services
Confirmed at consultation
Recirculation
Not published
Warranty
Series terms

Storage tanks can serve a recirculation loop with an external pump and return connection; Bradford White does not publish recirculation guidance for this model, so any loop is designed at consultation.

Where CANRO provides on-site service

On-site service is currently offered across Metro Vancouver: Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Delta, Langley, Port Moody, Port Coquitlam, Maple Ridge, Pitt Meadows, White Rock, Tsawwassen; plus Anmore, Belcarra, Lions Bay, Bowen Island, Abbotsford with travel or ferry arrangements confirmed by phone. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Bradford White. Manufacturer gallon and BTU/h figures are preserved with metric alongside; notes flag conflicting documents and missing figures. Groups expand for detail.

Storage capacity 2
Bradford White RG2DV40S6N specifications: Storage capacity
SpecificationValueNote
Rated nominal volume40 US gal (33 Imp. gal, 151 L)Canadian sheet C1105. Nominal, not the tested storage volume.
Rated (DOE) storage volume38 US gal (144 L)Published on the Canadian sheet C1105.
Delivery and recovery 3
Bradford White RG2DV40S6N specifications: Delivery and recovery
SpecificationValueNote
First-hour rating62 US gal (235 L)Single column on C1105, not fuel-specific. Based on AHRI directory listing.
Recovery at 90 °F (50 °C) rise, natural gas41 US gal/h (34 Imp. gal/h, 155 L/h)The sheet states 78% recovery efficiency for the family.
Recovery at 90 °F (50 °C) rise, propane (RG2DV40S6X)39 US gal/h (148 L/h)
Input 2
Bradford White RG2DV40S6N specifications: Input
SpecificationValueNote
Input, natural gas38,000 BTU/h11.1 kW.
Input, propane (RG2DV40S6X)36,000 BTU/h10.5 kW.
Efficiency 1
Bradford White RG2DV40S6N specifications: Efficiency
SpecificationValueNote
Uniform Energy Factor (UEF), medium draw0.6Per AHRI listing cited on C1105. Not ENERGY STAR (v5.0 requires UEF ≥ 0.81 for this size).
Venting and air 1
Bradford White RG2DV40S6N specifications: Venting and air
SpecificationValueNote
Vent connection3 in x 5 in (76 x 127 mm) co-axial direct ventClosed combustion: air in the outer pipe, exhaust in the inner pipe; side-wall termination with the manufacturer's vent kits.
Connections 3
Bradford White RG2DV40S6N specifications: Connections
SpecificationValueNote
Water connections3/4 in NPT with dielectric waterways and heat traps
Gas connection1/2 in (13 mm)
T&P relief valveFactory installed
Electrical 1
Bradford White RG2DV40S6N specifications: Electrical
SpecificationValueNote
Electrical supplyNone required (millivolt ICON System control powered by the pilot thermopile)
Physical 3
Bradford White RG2DV40S6N specifications: Physical
SpecificationValueNote
Height to top of heater50 3/16 in (1275 mm)Minimum 63 1/2 in (1613 mm) from the floor to the centre-line of the side-wall vent outlet.
Jacket diameter22 in (559 mm)Depth 31 in (787 mm) including fittings.
Shipping weight189 lb (86 kg)
Operating limits 2
Bradford White RG2DV40S6N specifications: Operating limits
SpecificationValueNote
Working pressure150 psi (1034 kPa); tested at 300 psi (2068 kPa)
CertificationCSA International
Other 1
Bradford White RG2DV40S6N specifications: Other
SpecificationValueNote
Anode rodMagnesium, combined with the hot-water outlet nipple

Manuals

Maintenance the manufacturer specifies

  • Inspect the anode rod every 2 years and replace when depleted; more often with softened water (manual, Maintenance item 9).
  • Operate the T&P relief valve at least once a year to check it lifts and reseats without leaking (item 6).
  • Drain about a gallon monthly to remove sediment (item 7); annual inspection by a qualified technician.
  • Inspect the vent system at least once a year; check burner flames twice a year (items 10 and 4).

Fault codes documented for this model

None documented yet.

Services

Hot water and scalding

  1. Water above 49 °C at a tap can scald in seconds, and children and older adults are at most risk. BC's plumbing code limits shower and bathtub water to 49 °C.
  2. Storage tanks are normally kept hotter (Health Canada advises 60 °C) to limit Legionella growth, with a thermostatic mixing valve tempering the water to the fixtures.
  3. Never bypass or remove a mixing valve, thermostat or high-limit control to get hotter water.

Official guidance: Government of Canada on water temperature and scalds and HealthLinkBC.

Frequently asked questions

Is the RG2DV40S6N sold in Canada?

Yes. It is listed on Bradford White's Canadian residential gas page and on Canadian spec sheet C1105. Bradford White sells only through wholesalers, so it is supplied and installed by contractors such as CANRO.

Does the RG2DV40S6N need electricity?

No. The co-axial vent draws combustion air from outside and the millivolt control runs on the pilot's thermopile, so hot water continues during a power outage.

Can the RG2DV40S6N run on propane?

The propane version is the RG2DV40S6X with a 36,000 BTU/h input. Fuel conversion is not a field procedure; order the correct fuel version.

Questions about the Bradford White RG2DV40S6N?

Describe what the water heater is doing and get a straight answer about the next step.

On-site service in Metro Vancouver, BC. Call to check availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.