Problem

Hot water temperature fluctuating

Water that runs hot, then cold, then hot has two common stories: a tankless unit asked to split its flow across fixtures it cannot serve at the current rise, or a storage tank with a dip-tube or control fault that lets cold water short-circuit to the outlet. This page separates the two and lists the checks.

Applies to:Gas storage tankGas tanklessElectric storage tank

Hot water and scalding

  1. Water above 49 °C at a tap can scald in seconds, and children and older adults are at most risk. BC's plumbing code limits shower and bathtub water to 49 °C.
  2. Storage tanks are normally kept hotter (Health Canada advises 60 °C) to limit Legionella growth, with a thermostatic mixing valve tempering the water to the fixtures.
  3. Never bypass or remove a mixing valve, thermostat or high-limit control to get hotter water.

Official guidance: Government of Canada on water temperature and scalds and HealthLinkBC.

Tankless: the flow conversation

A tankless unit holds temperature by modulating its burner against the flow it senses. Open a second fixture and the flow splits; if the combined demand exceeds what the unit can deliver at the current inlet temperature, the outlet temperature falls until the first fixture closes, then spikes back. That surging hot-cold-hot pattern is the signature of a unit at its flow limit, and in winter it appears at lower flows because the rise is larger.

The other tankless causes are mechanical: a fouled inlet filter or flow sensor makes the unit misread demand, and a scaled heat exchanger reduces output. If the pattern follows filter age or appeared after years of service, the descaling and filter service is the first step, with the flow-at-rise arithmetic checked at the same visit.

Storage tanks: temperature can go backwards

On a tank, temperature fluctuation at a shower is usually plumbing, not heating: a broken dip tube lets cold incoming water short-circuit straight up to the hot outlet, so the shower runs hot, then mixes cold, then recovers as the tank reheats. The same symptom can come from a crossed or failing mixing valve, or from two tanks or a recirculation loop mixing at the fixture.

A control that cannot hold temperature is the heater-side cause: a failing thermostat or gas control on a gas tank, or a failing element/thermostat pair on an electric tank. These are diagnosed by measuring outlet temperature over time rather than by replacing parts on the symptom.

What to record before calling

The pattern is the diagnosis. Note when the swing happens (only with two fixtures open? only in winter? only after the tank has been idle?), how wide the swing is, and whether any fixture is affected or just one. A fluctuation at one shower with everything else steady points at that shower's mixing valve; a whole-house swing points at the heater or the distribution.

Frequently asked questions

Why does my tankless shower surge when the dishwasher runs?

The unit is dividing its flow between two demands. If the combined flow exceeds its capacity at the current rise, the outlet temperature falls and then overshoots when the dishwasher finishes.

Can a mixing valve cause temperature swings?

Yes. A failing thermostatic mixing valve can let full storage temperature or full cold pass through, swinging the fixture temperature. That is a valve repair, not a heater fault.

Is temperature fluctuation dangerous?

Mostly it is uncomfortable. If the swing ever delivers water hot enough to scald, treat it as urgent: BC limits fixtures to 49 °C, and any failure that can pass 60 °C storage water to a shower needs fixing before use.