Problem
Gas burner will not ignite
A gas water heater that will not light has a short chain of suspects: gas supply, the pilot or ignition source, the flame-sensing circuit, or the control that sequences them. This page explains the chain, the codes and flash patterns that report it, and what is safe to check before calling.
If you smell gas
- Stop what you are doing. Do not use phones, switches, matches or anything that can spark inside.
- Go outside and leave the door open behind you.
- Call the FortisBC 24-hour emergency line at 1-800-663-9911 or dial 911.
Only after that, call CANRO about the water heater. Official guidance: FortisBC gas leaks and odour.
The ignition chain
Every gas water heater lights in the same order: gas must arrive at the correct pressure, the ignition source must spark or hold a pilot, the flame must be sensed, and the control must keep the gas valve open. A failure at any link stops the burner, and the symptoms differ: a pilot that will not light at all points at gas supply or the pilot assembly; a pilot that lights and goes out points at the thermocouple or thermopile; a burner that never fires with the pilot lit points at the thermostat or gas control.
Tankless units report the same chain as codes: Rinnai's code 11 is No Ignition and code 12 is No Flame, and the checks the manual lists run from the gas supply to the igniter, flame rod and gas solenoids. A code is the starting point for the diagnosis, never the diagnosis itself.
Safe homeowner checks
Before calling, confirm the obvious supply items: the gas valve at the heater is open, other gas appliances work, the propane tank has gas, and the unit has power (a display lit or an LED pattern visible). On a standing-pilot tank, the manufacturer's lighting procedure in the manual is a homeowner step, and a thermocouple that fails right after lighting is the classic cause of a pilot that will not stay lit.
Stop at the point the manual stops: gas pressure adjustment, orifice changes, igniter and flame-rod work, and opening the gas train are licensed-gas-fitter work.
Why repeated attempts are the wrong test
Repeatedly resetting a tankless unit or relighting a stubborn pilot does not fix the cause and, on some controls, extends lockout timing. The useful information for the technician is the code, the flash pattern, whether the unit fires at all, and what changed recently: a new gas line, a tank swap, or a propane fill are all classic ignition-failure triggers.
Frequently asked questions
My pilot lights but goes out when I release the button. What is that?
The thermocouple or thermopile is not producing enough voltage to hold the gas valve open, or the pilot flame is not reaching it. Both are technician checks, and a thermocouple replacement is the common fix.
Can air in the gas line stop ignition?
Yes. After a new tank, a new line or a gas shut-off, air must be purged from the line before the burner will stay lit; a licensed gas fitter does the purge and checks the pressure.
What if I smell gas during all this?
Stop immediately, do not touch switches, leave the building, and call FortisBC at 1-800-663-9911 or 911 from outside.
Talk to a water heater technician
Describe what the water heater is doing and get a straight answer about the next step.
On-site service in Metro Vancouver, BC. Call to check availability.
Sources and verification
- CANRO Heating & Cooling — About · Canadian source · accessed September 7, 2026
- FortisBC — gas leaks and odour · Canadian source · accessed September 7, 2026
- Bradford White Installation and Operation Manual (lighting instructions) · 238-51012-00V · accessed September 7, 2026
- Rinnai RU series Installation and Operation Manual (codes 11 and 12) · 100000467 · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.