Both are Canadian-market 40 US gallon (151 L) atmospheric-vent natural gas storage tanks with a 40,000 BTU/h input on natural gas, and both are offered on propane. They are the same size and venting class, so the practical difference is what each manufacturer publishes. Bradford White publishes a 75 US gallon (284 L) first-hour rating, UEF 0.64 and full dimensions for the RG240T6N; Giant publishes the UG40's capacity, input and 6-year warranty but no first-hour rating, energy factor or dimensions. That makes sizing the Giant a demand-assessment job rather than a spec-sheet comparison.

Side by side

Published manufacturer figures with units. Storage and flow figures are different measures and are shown on their own rows; blanks mean not applicable or not published.

Comparison of Giant UG40 and Bradford White RG240T6N
SpecificationGiant UG40Gas storage tankBradford White RG240T6NGas storage tank
Storage capacity40 US gal (151 L)40 US gal (33 Imp. gal, 151 L)
First-hour rating75 US gal (284 L)
Recovery at 90 °F (50 °C) rise, natural gas43 US gal/h (36 Imp. gal/h, 163 L/h)
Input, natural gas40,000 BTU/h
Input, natural gas40,000 BTU/h
Uniform Energy Factor (UEF), medium draw0.64
VentingAtmospheric; air is drawn from inside the home and exhaust vents into a chimney3 in or 4 in (76 or 102 mm) draft hood
Gas connection1/2 in (13 mm)
Height to top of heater56 5/8 in (1438 mm)
Jacket diameter20 in (508 mm)
Shipping weight134 lb (61 kg)
Electrical supplyNone required (millivolt control powered by the pilot thermopile)
Warranty (Giant published)6 years against inner tank leakage; 6 years on component parts, from the date of installation

“—” means not applicable to that system type or not published by the manufacturer. Flow figures are only comparable at the same temperature rise; UEF values are only comparable within the same draw pattern.

What actually separates them

Both models are 40 US gallon (151 L) atmospheric-vent tanks with a 40,000 BTU/h input on natural gas, so at the same burner input the recovery rate is the same in principle and the delivered volume comes down to storage and published data. Bradford White publishes a 75 US gallon (284 L) first-hour rating and 43 US gal/h recovery at a 90 °F (50 °C) rise. Giant's Canadian page states the 40 US gallon capacity and the 40,000 BTU/h input but does not publish a first-hour rating, recovery rate, energy factor or dimensions for the UG40, so those cells stay blank here rather than being estimated.

Efficiency is where the published gap shows. Bradford White lists UEF 0.64 under the medium-draw test and states the model is not ENERGY STAR, since version 5.0 requires UEF 0.81 for gas storage tanks of this size. Giant does not publish an energy factor or UEF for the UG40, so WaterHeating.ca states none; a Giant proposal is sized on the demand assessment, not on a brochure number.

Venting and power are the same class. Both vent by natural draft into a chimney or B-vent and draw combustion air from the room, and neither needs a standing electrical supply: Giant lists a thermopile pilot with a piezoelectric push-button igniter, and Bradford White uses a millivolt control powered by the pilot thermopile. Both therefore keep heating during a power outage, unlike a power-vent or tankless unit.

Fuel and warranty differ in detail. Giant lists the UG40 at the same 40,000 BTU/h input for natural gas and propane, while Bradford White's propane version, the RG240T6X, is 36,000 BTU/h with lower recovery; on either model the correct fuel version is ordered, because field conversion is not a procedure. Giant states a 6-year inner-tank and 6-year parts warranty from the date of installation, and Bradford White lists a 10-year-warranty variant of the same tank, the RG240T10N. The warranty sheet for the exact unit governs. Whether CANRO supplies either model for a given job is confirmed at consultation, and no price is published here.

Giant · Gas storage tank

Giant UG40

CurrentSold in Canada
Nominal capacity
40 US gal (151 L)
First-hour delivery
Input

The Giant UG40 is a 40 US gallon (151 L) atmospheric-vent natural gas or propane storage water heater with a 40,000 BTU/h input, a glass-lined tank, FVIR technology and a 6-year tank and parts warranty, made in Canada by Giant.

Natural gasPropaneAtmospheric (draft hood)

Bradford White · Gas storage tank

Bradford White RG240T6N

CurrentSold in Canada
Nominal capacity
40 US gal (33 Imp. gal, 151 L)
First-hour delivery
75 US gal (284 L)
Input
40,000 BTU/h

The Bradford White RG240T6N is a 40 US gallon (151 L) atmospheric-vent natural gas storage water heater with a 40,000 BTU/h input, 75 US gallon first-hour rating and UEF 0.64, sold in Canada through wholesale channels. It is the like-for-like replacement for most 40-gallon gas tanks in older Metro Vancouver homes.

Natural gasPropaneAtmospheric (draft hood)

Frequently asked questions

Are the Giant UG40 and Bradford White RG240T6N the same size?

Yes. Both are 40 US gallon (151 L) atmospheric-vent storage tanks with a 40,000 BTU/h natural gas input. They differ in what each manufacturer publishes: Bradford White publishes a 75 US gallon (284 L) first-hour rating and UEF 0.64, while Giant publishes neither for the UG40.

Why does the table show blanks for the Giant UG40?

Because Giant's Canadian product page for the UG40 does not publish a first-hour rating, recovery rate, energy factor, dimensions or weight. Those cells stay blank rather than being estimated; sizing on this model is confirmed in a demand assessment.

Which one works in a power outage?

Both. Giant lists a thermopile pilot with a push-button igniter and Bradford White uses a millivolt control powered by the pilot, so neither needs mains power and both keep heating during an outage.

Can I get either on propane?

Yes. Giant lists the UG40 for natural gas and propane at the same 40,000 BTU/h. Bradford White's propane version is the RG240T6X at 36,000 BTU/h with lower recovery. Order the correct fuel version; field conversion is not a procedure on these models.

Not sure which one fits your home?

A consultation includes a hot-water demand review so capacity is right for your winter, not the brochure's.

On-site service in Metro Vancouver, BC. Call to check availability.

Call 604-359-1081Get Estimate