Bradford White eF RC2PV50H6N vs Defender RG2PV50H6N19 (50 gal power vent)

Verdict in brief

Both are 50 US gallon-class through-the-wall power vent natural gas tanks from Bradford White's Canadian line, and the real split is condensing versus non-condensing. The eF Series RC2PV50H6N is a condensing unit: UEF 0.80, 76,000 BTU/h, a 120 US gallon first-hour rating and 2/3/4 in PVC-family venting with a condensate drain. The Defender RG2PV50H6N19 is a non-condensing positive-pressure power vent: UEF 0.68, 65,000 BTU/h, a 116 US gallon first-hour rating and 3/4 in PVC/ABS/CPVC/polypropylene venting. Choose the eF for lower gas use where a condensate path exists, the Defender for the simpler non-condensing vent.

Side by side

Published manufacturer figures with units. Storage and flow figures are different measures and are shown on their own rows; blanks mean not applicable or not published.

Comparison of Bradford White RC2PV50H6N and Bradford White RG2PV50H6N19
SpecificationBradford White RC2PV50H6NGas storage tankBradford White RG2PV50H6N19Gas storage tank
Rated nominal volume50 US gal (42 Imp. gal, 190 L)48 US gal (42 Imp. gal, 182 L)
First-hour rating120 US gal (455 L)116 US gal (440 L)
Recovery at 90 °F (50 °C) rise, natural gas91 US gal/h (344 L/h)70 US gal/h (58 Imp. gal/h, 265 L/h)
Input, natural gas76,000 BTU/h65,000 BTU/h
Uniform Energy Factor (UEF), medium draw0.80.68
Vent connection2 in, 3 in or 4 in (51, 76 or 102 mm) PVC-family3 in or 4 in (76 or 102 mm) PVC, ABS, CPVC or polypropylene
Maximum equivalent vent length75 ft (23.0 m) in 3 in; 180 ft (55.0 m) in 4 in
Height to top of heater56 1/4 in (1429 mm)56 3/4 in (1441 mm)
Jacket diameter24 in (610 mm)22 in (559 mm)
Shipping weight225 lb (102 kg)187 lb (85 kg)
Electrical supply120 V required for the blower and control120 VAC, 60 Hz, 3.1 A
CertificationCSA International design certifiedCSA International, ANSI Z21.10.1 / CSA 4.1

“—” means not applicable to that system type or not published by the manufacturer. Flow figures are only comparable at the same temperature rise; UEF values are only comparable within the same draw pattern.

What actually separates them

Both are indoor storage tanks for homes without a usable chimney, both vent through the wall under positive pressure, and both need a 120 V supply for the blower and control, so neither makes hot water during a power outage. The difference is the heat exchanger. The eF RC2PV50H6N is condensing, with a dual-pass exchanger that recovers latent heat for UEF 0.80; the Defender RG2PV50H6N19 is a conventional non-condensing tank at UEF 0.68. Both figures are Uniform Energy Factors on the medium draw pattern, so they are comparable to each other, and the gap is directional rather than a promised saving.

Input and delivery follow the efficiency class. The eF runs a 76,000 BTU/h input on the same nominal 50 US gallon tank, for a 120 US gallon (455 L) first-hour rating and about 91 US gal/h (344 L/h) of recovery at a 90 °F rise. The Defender runs 65,000 BTU/h on a 48 US gallon nominal tank, for a 116 US gallon (440 L) first-hour rating and about 70 US gal/h (265 L/h) of recovery. The eF therefore recovers roughly a third faster, which is what the higher input buys.

Venting and physical size differ more than the labels suggest. The eF condensing unit vents in 2, 3 or 4 in PVC-family pipe and produces acidic condensate, so it needs a condensate drain to an approved location with a neutralizer where required. The Defender is non-condensing, vents in 3 or 4 in PVC, ABS, CPVC or polypropylene up to 180 equivalent feet in 4 in, and produces no condensate. The eF is the wider and heavier cabinet at 24 in diameter and 225 lb against 22 in and 187 lb for the Defender, both about 56 in to the top of the heater. Both are CSA International design certified.

The honest decision is about the site and the gas bill. Where a condensate path is available and lower gas use is wanted, the condensing eF is the better fit; where the simpler non-condensing power vent suits the budget and there is no convenient condensate route, the Defender is the lower-complexity choice. UEF 0.80 is just under the ENERGY STAR version 5.0 threshold of 0.81 for this size, so neither is presented here as ENERGY STAR. Whether CANRO supplies a given model for a specific job is confirmed at consultation.

Bradford White · Gas storage tank

Bradford White RC2PV50H6N

CurrentSold in Canada
Nominal capacity
50 US gal (42 Imp. gal, 190 L)
First-hour delivery
120 US gal (455 L)
Input
76,000 BTU/h

The Bradford White RC2PV50H6N is a 50 US gallon (190 L) condensing power vent natural gas storage water heater with a 76,000 BTU/h input, 120 US gallon first-hour rating and UEF 0.80, sold in Canada through wholesale channels. PVC-family venting and a condensate drain replace the chimney.

Natural gasPropaneCondensing, PVC/CPVC/PP

Bradford White · Gas storage tank

Bradford White RG2PV50H6N19

CurrentSold in Canada
Nominal capacity
48 US gal (42 Imp. gal, 182 L)
First-hour delivery
116 US gal (440 L)
Input
65,000 BTU/h

The Bradford White RG2PV50H6N19 is a 48 US gallon (182 L) high-input through-the-wall power vent natural gas storage water heater with a 65,000 BTU/h input, 116 US gallon first-hour rating and UEF 0.68, sold in Canada under the current 19-suffix model numbers. It adds space-heating connections to the Defender power vent family.

Natural gasPropanePower vent

Frequently asked questions

Which of these two is more efficient?

The eF RC2PV50H6N at UEF 0.80 against the Defender RG2PV50H6N19 at UEF 0.68. Both are medium-draw Uniform Energy Factors, so they are comparable, and the gap is directional rather than a savings percentage. The eF is the condensing unit; the Defender is not.

Does the condensing eF need a condensate drain?

Yes. A condensing unit produces acidic condensate that must drain to an approved location, with a neutralizer where required. The non-condensing Defender does not produce condensate, which is one reason it is the simpler install.

Can either replace a tank that vented into a chimney?

Both are through-the-wall power vents designed for homes without a usable chimney. The eF needs a condensate path in addition to its PVC-family vent; the Defender does not.

Not sure which one fits your home?

A consultation includes a hot-water demand review so capacity is right for your winter, not the brochure's.

On-site service in Metro Vancouver, BC. Call to check availability.