Bradford White RG2D40S6N (40 gal) vs RG2D50S6N (50 gal) damper tanks

Verdict in brief

The two members of Bradford White's Canadian damper atmospheric line behave differently from most size pairs. The 50-gallon RG2D50S6N is both the bigger and the better performer: 81 US gal (307 L) first-hour and UEF 0.68 on a 40,000 BTU/h input, against 62 US gal (235 L) and UEF 0.64 for the 40-gallon RG2D40S6N on 38,000 BTU/h. The 40-gallon damper model actually trails the plain 40-gallon atmospheric RG240T6N on first-hour delivery, so the damper's gain is standby loss, not busy-hour output. Both need 120 VAC for the flue damper and stop heating in an outage.

Side by side

Published manufacturer figures with units. Storage and flow figures are different measures and are shown on their own rows; blanks mean not applicable or not published.

Comparison of Bradford White RG2D40S6N and Bradford White RG2D50S6N
SpecificationBradford White RG2D40S6NGas storage tankBradford White RG2D50S6NGas storage tank
Rated nominal volume40 US gal (151 L)50 US gal (42 Imp. gal, 189 L)
Rated (DOE) storage volume38 US gal (144 L)47 US gal (178 L)
First-hour rating62 US gal (235 L)81 US gal (307 L)
Recovery at 90 °F (50 °C) rise41 US gal/h (155 L/h)43 US gal/h (163 L/h)
Input, natural gas38,000 BTU/h40,000 BTU/h
Uniform Energy Factor (UEF), medium draw0.640.68
Vent connection3 in or 4 in (76 or 102 mm) draft hood with automatic flue damper3 in or 4 in (76 or 102 mm) draft hood with automatic flue damper
Electrical supply120 VAC, 60 Hz (10 ft power cord included) for the automatic damper and ICON control120 VAC, 60 Hz (10 ft power cord included) for the automatic damper and ICON control
Height to top of heater47 11/16 in (1211 mm)56 9/16 in (1437 mm)
Jacket diameter22 in (559 mm)22 in (559 mm)
Shipping weight155 lb (70 kg)174 lb (79 kg)

“—” means not applicable to that system type or not published by the manufacturer. Flow figures are only comparable at the same temperature rise; UEF values are only comparable within the same draw pattern.

What actually separates them

An automatic flue damper closes the vent passage while the burner is off, so heated room air and residual tank heat stop flowing up the chimney, and it opens before the burner fires. The sheet credits the design with reduced standby loss, which shows up as UEF 0.68 on the 50-gallon model against 0.63 for the plain atmospheric RG250T6N at the same 40,000 BTU/h input and capacity. That is a real five-point gain under the same medium-draw test.

The two sizes in this family do not follow the usual pattern. The 50-gallon damper tank delivers 81 US gal (307 L) in the first hour, the same figure as the plain 50-gallon RG250T6N, while the 40-gallon damper tank delivers 62 US gal (235 L), well below the plain 40-gallon RG240T6N's 284 L. The 40-gallon damper model is therefore the one case in the line where the damper's benefit in standby comes with a first-hour figure below a plain tank of the same size. Buyers whose constraint is busy-hour delivery, not standby loss, should compare it with the plain atmospheric models before choosing.

Both are Defender Safety System FVIR tanks with the ICON electronic control and no standing pilot. The damper and control run on 120 VAC from an included 10 ft (3 m) power cord, so each needs a receptacle and neither makes hot water during a power outage, unlike the millivolt atmospheric tanks that run on the pilot thermopile. Venting is a 3 in or 4 in draft diverter into a chimney or B-vent, so a sound flue and room combustion air are still required.

Fit and weight separate the pair more than efficiency does. The 40-gallon model stands 47 11/16 in (1211 mm) to the top of the heater in a 22 in jacket and ships at 155 lb; the 50-gallon model stands 56 9/16 in (1437 mm) in the same 22 in jacket and ships at 174 lb, so ceiling height is the practical constraint rather than width. Both carry a 6-year tank and parts warranty with no labour, and both need the anode inspected every two years.

Bradford White · Gas storage tank

Bradford White RG2D40S6N

CurrentSold in Canada
Nominal capacity
40 US gal (151 L)
First-hour delivery
62 US gal (235 L)
Input
38,000 BTU/h

The Bradford White RG2D40S6N is a 40 US gallon (151 L) damper atmospheric-vent natural gas storage water heater with a 38,000 BTU/h input, 62 US gallon first-hour rating and UEF 0.64, sold in Canada through wholesale channels. An automatic flue damper closes during standby to cut heat loss up the chimney.

Natural gasPropaneAtmospheric (draft hood)

Bradford White · Gas storage tank

Bradford White RG2D50S6N

CurrentSold in Canada
Nominal capacity
50 US gal (42 Imp. gal, 189 L)
First-hour delivery
81 US gal (307 L)
Input
40,000 BTU/h

The Bradford White RG2D50S6N is a 50 US gallon (189 L) damper atmospheric-vent natural gas storage water heater with a 40,000 BTU/h input, 81 US gallon first-hour rating and UEF 0.68, sold in Canada through wholesale channels. An automatic flue damper closes during standby to cut heat loss up the chimney.

Natural gasPropaneAtmospheric (draft hood)

Frequently asked questions

Which damper tank delivers more in a busy hour?

The 50-gallon RG2D50S6N, at 81 US gal (307 L) against 62 US gal (235 L) for the 40-gallon RG2D40S6N. The 40-gallon damper model's first-hour figure is also below the plain 40-gallon atmospheric RG240T6N's 284 L, so it is chosen for standby savings, not peak output.

Why is the 50-gallon damper tank more efficient than the 40-gallon?

The Canadian sheet rates the 50-gallon model UEF 0.68 against 0.64 for the 40-gallon, both medium-draw. The damper closes a larger flue passage on the bigger tank, and the sheet credits the design with reduced standby loss. Both remain below ENERGY STAR.

Do the damper models need electricity?

Yes. The automatic flue damper and ICON control run on 120 VAC from the included 10 ft power cord, so the unit needs a receptacle and does not heat water during a power outage. That differs from the plain atmospheric tanks, which can run on the pilot thermopile with no mains supply.

Not sure which one fits your home?

A consultation includes a hot-water demand review so capacity is right for your winter, not the brochure's.

On-site service in Metro Vancouver, BC. Call to check availability.

Sources and verification

Facts checked September 21, 2026. Last updated September 21, 2026. Technical reviewer: not yet assigned.

Call 604-359-1081Get Estimate